Standards Sheet PDF Print

HERITAGE COLLECTION

STANDARD FEATURES

 

 INTERIOR

  • 8 Foot ceiling height
  • Smooth 1/2” drywall throughout
  • Smooth 5/8” drywall ceilings throughout
  • Painted drywall walls & ceiling (one coat primer)
  • White MDF colonial 2 ¼” molding at windows & doors
  • Picture frame window casing
  • White MDF colonial 3 ¼” base molding throughout
  • White wood window & door jambs
  • White 6 panel doors
  • 30” interior passage doors
  • Nickel privacy locks on all bath doors
  • Nickel door stop bumpers for all doors
  • 25 oz FHA grade carpet throughout (except wet areas)
  • Dupont stain protected carpet
  • 5.5 lb Rebond carpet pad
  • Tack strip carpet installation
  • Vinyl floor coverings in foyer entry, kitchen, morning rooms, baths & utility
  • Wire shelves in all closets (pantry & linens have 3)
  • Nickel base & globe interior lights (NI- 6)
  • Glass & nickel dome light (NI- 9) in laundry room, J- box & switch in dinning

 

 KITCHEN

  • KCMA approved residential panel oak cabinets & drawers with oak shelves
  • ½ depth adjustable shelves in base for extra storage
  • Adjustable wall cabinet ½” shelves
  • Concealed hinges on cabinets doors
  • Laminate counter tops w/ self edge and 4” backsplash
  • 7” deep double stainless steel sink
  • Single lever faucet with spray, std. grade
  • 36” wide refrigerator opening
  • Wire for electric range
  • GFI wired kitchen receptacles
  • Nickel base (NI- 6) drum light over sink and in the center of the kitchen
  • Standard appliance package (Dishwasher, Range and Microwave/ Hood)

 

 BATHS

  • Fiberglass tubs and or showers in all baths
  • 60” fiberglass tub/ shower in main bath
  • Fiberglass garden tub (some models)
  • Fiberglass corner tub with separate shower stall (some models)
  • Single lever faucet at lavs, std grade
  • Single lever anti- scald faucet on showers, std. grade
  • Porcelain vanity bowls in all baths
  • Pop up drain assemblies in all vanity bowls and tubs
  • GFI wired bath receptacles 
  • Power vent ceiling fans with lights
  • Beveled mirror over all vanity bowls
  • Nickel sconce light over all vanity bowls (NI- 24)
  • 1.6 gallon porcelain elongated bowl toilets
  • Panel oak cabinets in all baths
  • Bath window in master bath std in Norfolk model only

 

UTILITIES

  • Ten- Year structural warranty
  • Full size 200 amp main service with circuit breaker protection
  • GFI protection for 2 exterior receptacles (1 front & 1 rear)
  • Plumbing for washer
  • Wire for dryer
  • Ac/ DC smoke detectors (per code)
  • Water shut off valves throughout
  • Bi- fold doors in washer dryer area (some plans)
  • Switched receptacle in each bedroom
  • Complete 13 Seer Heat Pump System, with 10 kw strip heater (back up). Sized accordingly
  • 50 gallon electric hot water heater
  • 2 phone jacks w/ cat 5 network wire
  • 2 television cable hook ups

 

EXTERIOR AND CONSTRUCTION

  • Front covered porch w/ vinyl rail and spindles. Concrete slab, steps to be composite
  • Rear landing and steps (salt- treated)
  • Joist hangers on mating wall floor joists with bridging
  • 1st floor- 2x10 floor joist @ 16” O. C.
  • 2x6 exterior walls @ 16” O. C.
  • 7/16 OSB sheathing on all exterior walls
  • Sub floor ¾” (nominal) floor decking
  • 2x4 interior partitions @ 24” O. C.
  • Double marriage walls 8” (2x4) 24” O. C.
  • 7/16” OSB roof sheathing with H- clips
  • Ply dry shingle underlayment
  • Ice shield
  • 25 year self sealing fiberglass roof shingles
  • Shingle over roof vent
  • 12” vented overhangs on front and rear w/ vinyl soffits
  • 12” vented overhangs on gable ends w/ vinyl soffits
  • 6” aluminum fascia over 2x6 for gutter mounting
  • Vinyl thermopane windows with screens, bottom tilt & tilt to wash
  • Low – E glass
  • 6- panel 3/0x6/8 insulated fiberglass front door w/ peep hole
  • 6- panel 2/8x6/8 insulated fiberglass rear door
  • Door pans on all exterior doors
  • 6/0 x6/8 vinyl sliding patio door w/ screens (some models)
  • Stainless steel torch light by the front & rear doors
  • 4x4 vinyl siding
  • Crawl space w/ vapor barrier standard
  • 3 dormers standard on the Norfolk model only
  • Energy star inspection package

 

INSULATION

  • R- 30 insulation w/ vapor barrier in ceiling
  • R- 19 fiberglass insulation (6”) w/ vapor barrier in sidewalls
  • R- 19 fiberglass insulation (6”) w/ vapor barrier in first floor joist
  • Foam gasket on all exterior wall receptacles and switches
  • Seal around windows to stop air infiltration caulk seams on exterior sheathing
  • Foam gasket on marriage wall perimeter

 

Clover Development L. L. C. continuously strives to improve its product. For this reason,

all features, design, specifications and prices are subject to change without notice.

 

 

 
All content Copyright © 2010 - Hosting by Seabreeze Hosting - Terms and Conditions
Clover Development L. L. C. continuously strives to improve its product.
For this reason, all features, design, specifications and prices are subject
to change without notice.